资源类型

期刊论文 120

会议视频 2

年份

2023 9

2022 22

2021 4

2020 15

2019 6

2018 7

2017 17

2016 1

2015 8

2014 3

2013 3

2012 4

2011 6

2010 3

2008 3

2007 3

2000 4

1999 1

展开 ︾

关键词

分子成像 2

成像 2

4Pi-SMLM 1

4Pi超分辨显微术 1

CCS 1

CO2-ECBM 1

ToF);散射介质;拐角遮挡 1

Vidar相机 1

X 射线成像 1

X射线成像 1

isoSTED 1

一氧化碳氧化 1

中国微生物组计划 1

互养菌(Syntrophus 1

互营杆菌(Syntrophorhabdaceae) 1

亚甲基蓝 1

人脑功能磁共振 1

低剂量CT;CT成像;全变分;稀疏字典学习 1

偏振;图像增强;散射;粒子 1

展开 ︾

检索范围:

排序: 展示方式:

Carbon dots-based fluorescence sensor for two-photon imaging of pH in diabetic mice

《化学科学与工程前沿(英文)》 2023年 第17卷 第3期   页码 298-306 doi: 10.1007/s11705-022-2212-9

摘要: Herein, a reversible pH fluorescent sensor was developed using caffeic acid as the precursor by one-step solvothermal synthesis method. The carbon dots-based sensor (CA-CDs) exhibited pH-dependent increase in fluorescence intensity and showed linear relationship in the range of pH 6.60 and 8.00. Notably, the fluorescence sensor has a reversible response to pH change. Finally, the CA-CDs has been successfully applied for two-photon imaging of the pH in liver and kidney of diabetic mice. Imaging results showed that the pH value in kidney of diabetic mice was lower than that of the normal mice, while the pH value in liver of diabetic mice was almost the same as that of the normal mice. The present study provides a simple analytical method for pH detection suitable for in vivo.

关键词: carbon dots     two-photon imaging     pH     diabetic mice    

A highly selective fluorescent probe for real-time imaging of UDP-glucuronosyltransferase 1A8 in living

《化学科学与工程前沿(英文)》 2022年 第16卷 第1期   页码 103-111 doi: 10.1007/s11705-021-2064-8

摘要: Uridine diphosphate (UDP)-glucuronosyltransferases (UGTs) are enzymes involved in the biotransformation of important endogenous compounds such as steroids, bile acids, and hormones as well as exogenous substances including drugs, environmental toxicants, and carcinogens. Here, a novel fluorescent probe BDMP was developed based on boron-dipyrromethene (BODIPY) with high sensitivity for the detection of UGT1A8. The glucuronidation of BDMP not only exhibited a red-emission wavelength (λex/λem = 500/580 nm), but also displayed an excellent UGT1A8-dependent fluorescence signal with a good linear relationship with UGT1A8 concentration. Based on this perfect biocompatibility and cell permeability, BDMP was successfully used to image endogenous UGT1A8 in human cancer cell lines (LoVo and HCT15) in real time. In addition, BDMP could also be used to visualize UGT1A8 in tumor tissues. These results suggested that BDMP is a promising molecular tool for the investigation of UGT1A8-mediated physiological function in humans.

关键词: UDP-glucuronosyltransferase 1A8     fluorescent probe     subtype selectivity     fluorescence imaging    

SWIR Fluorescence Imaging In Vivo Monitoring and Evaluating Implanted M2 Macrophages in Skeletal Article

Mo Chen, Yuzhou Chen, Sijia Feng, Shixian Dong, Luyi Sun, Huizhu Li, Fuchun Chen, Nguyen Thi Kim Thanh, Yunxia Li, Shiyi Chen, You Wang, Jun Chen

《工程(英文)》 doi: 10.1016/j.eng.2023.05.010

摘要:

Skeletal muscle has a robust regeneration ability that is impaired by severe injury, disease, and aging, resulting in a decline in skeletal muscle function. Therefore, improving skeletal muscle regeneration is a key challenge in treating skeletal muscle-related disorders. Owing to their significant role in tissue regeneration, implantation of M2 macrophages (M2Mø) has great potential for improving skeletal muscle regeneration. Here, we present a short-wave infrared (SWIR) fluorescence imaging technique to obtain more in vivo information for an in-depth evaluation of the skeletal muscle regeneration effect after M2Mø transplantation. SWIR fluorescence imaging was employed to track implanted M2Mø in the injured skeletal muscle of mouse models. It is found that the implanted M2Mø accumulated at the injury site for two weeks. Then, SWIR fluorescence imaging of blood vessels showed that M2Mø implantation could improve the relative perfusion ratio on day 5 (1.09 ± 0.09 vs 0.85 ± 0.05; p = 0.01) and day 9 (1.38 ± 0.16 vs 0.95 ± 0.03; p = 0.01) post-injury, as well as augment the degree of skeletal muscle regeneration on day 13 post-injury. Finally, multiple linear regression analyses determined that post-injury time and relative perfusion ratio could be used as predictive indicators to evaluate skeletal muscle regeneration. These results provide more in vivo details about M2Mø in skeletal muscle regeneration and confirm that M2Mø could promote angiogenesis and improve the degree of skeletal muscle repair, which will guide the research and development of M2Mø implantation to improve skeletal muscle regeneration.

关键词: In vivo     Short-wave infrared     Skeletal muscle     Macrophage     Regeneration    

荧光显纳镜在神经科学中的应用 Review

王杨云逗, 林剑, 张启明, 陈希, 栾海涛, 顾敏

《工程(英文)》 2022年 第16卷 第9期   页码 29-38 doi: 10.1016/j.eng.2020.11.010

摘要:

荧光显纳技术提供了克服光学显微镜中衍射极限分辨率障碍的成像技术,从而开辟了生物医学成像研究领域(尤其在神经科学领域)。本文回顾了最重要的荧光显纳技术,包括描述了该技术在阐明蛋白质结构和流动性、神经活动过程中涉及突触参数的实时测定、三维成像和纳米级神经活动跟踪等方面的应用。最后,讨论了荧光显纳镜的前景,特别关注该技术在神经科学中与相关技术(如机器学习)的结合。

关键词: 荧光成像     衍射极限     纳米级分辨率     神经科学    

evaluation of renal function using diffusion weighted imaging and diffusion tensor imaging in type 2

null

《医学前沿(英文)》 2014年 第8卷 第4期   页码 471-476 doi: 10.1007/s11684-014-0365-8

摘要:

This work aims to estimate the value of diffusion weighted imaging (DWI) and diffusion tensor imaging (DTI) in detecting early-stage kidney injury in type 2 diabetic patients with normoalbuminuria (NAU) versus microalbuminuria (MAU) prospectively. A total of 30 T2DM patients with normal kidney function were recruited and assigned to the NAU group (n = 14) or MAU group (n= 16) according to 8 h overnight urinary albuminuria excretion rate (AER) results. A contemporary cohort of health check-up recipients were included as controls (n = 12). DWI and DTI scans were performed on bilateral kidney using SE single-shot EPI, and apparent diffusion coefficient (ADC) and fractional anisotropy (FA) of the renal parenchyma was determined from ADC and FA maps of the three groups. ADC and FA values were compared among the three groups. According to DWI with a b value of 400 s/mm2, the MAU and NAU groups showed significantly lowered mean ADC values compared with the healthy controls (P<0.01). The mean ADC in the MAU group [(2.22±0.07)×10–3 mm2/s] was slightly lower than that of the NAU group [(2.31±0.22)×10–3 mm2/s], but this difference was not statistically significant (P>0.05). The FA value in the MAU group was higher than that in the control group (0.45±0.07 vs. 0.39±0.03, = 0.004) but did not differ from that in the NAU group (0.42±0.03) (P>0.05). ADC and FA values may be more sensitive than urine AER in reflecting early-stage kidney injury and, hence, may facilitate earlier detection and quantitative evaluation of kidney injury in T2DM patients. Combined evaluation of ADC and FA values may provide a better quantitative approach for identifying diabetic nephropathy at early disease stages.

关键词: type 2 diabetes mellitus     microalbuminuria     diffusion weighted imaging     diffusion tensor imaging     early-stage kidney injury    

基于临床可用的亚甲基蓝近红外二区成像用于泌尿系统结构及功能成像的研究 Article

薛丁玮, 吴迪, 陆泽毅, Jochen Neuhaus, 阿卜杜热合曼·则比布拉, 冯哲, 成晟, 周静, 钱骏, 李恭会

《工程(英文)》 2023年 第22卷 第3期   页码 149-158 doi: 10.1016/j.eng.2021.07.032

摘要:

精准的结构和功能成像对于泌尿系统疾病的诊断和预后至关重要。近红外二区光谱区域(second nearinfrared spectral region, NIR-II, 1000~1700 nm)荧光生物成像相较于传统的荧光生物成像具有更高的空间分辨率、更深的穿透力和更好的信噪比,但其临床适用性有限。在此,本文首次报道了基于临床可用且经肾脏排泄的荧光染料亚甲基蓝(methylene blue, MB)对活体泌尿系统进行NIR-II 荧光成像,该技术不仅可实现清晰的有创/无创尿路造影,而且还能有效且无创地检测肾功能。以上研究结果表明MB辅助的NIR-II 荧光成像在临床/基础研究中泌尿系统结构和功能成像领域中具有较大的应用前景。

关键词: 近红外二区荧光     亚甲基蓝     肾功能     泌尿系统     实时成像    

Synthesis and fluorescence behavior of 2,5-diphenyl-1,3,4-oxadiazole-containing bismaleimides and bissuccinimides

Xin ZHANG, Zichen LI

《化学科学与工程前沿(英文)》 2013年 第7卷 第4期   页码 381-387 doi: 10.1007/s11705-013-1359-9

摘要: Bismaleimides bearing 2,5-diphenyl-1,3,4-oxadiazole chromophores at , , position and corresponding saturated bissuccinimides were synthesized. Several synthetic strategies for these bismaleimides were discussed in detail. Almost no or very weak fluorescence was observed for these bismaleimides, however, the bissuccinimides show a strong fluorescence. The effect of molecular geometry on optical behavior and fluorescence quenching mechanism were investigated by UV-vis absorption and fluorescence emission spectroscopy. The electron coupling of ground state of -bismaleimide is stronger than those of - and -bismaleimides. -Bissuccinimide displays increasing fluorescence quantum yields with red shifts of 22–24 nm, compared to -bissuccinimide. Polymerizable C=C bonds play a key role in the intramolecular fluorescence quenching.

关键词: fluorescence     bismaleimide     oxadiazole     succinimide    

荧光碳点的快速宏量制备及多功能应用 Article

王丹,王志勇,詹求强,蒲源,王洁欣,Neil R. Foster,戴黎明

《工程(英文)》 2017年 第3卷 第3期   页码 402-408 doi: 10.1016/J.ENG.2017.03.014

摘要:

荧光纳米材料在化学传感、生物成像及光电器件等领域具有重要应用前景,其合成方法的研究得到广泛关注。我们采用柠檬酸和乙二胺作为原料,在150 ℃、常压的相对温和条件下,通过“一锅法”反应制备了氮掺杂荧光碳点。所得荧光碳点光学带隙为3.4 eV,在单光子或双光子激发下呈现出明亮的荧光,且荧光发射波长稳定(λ = 450 nm)。基于荧光碳点低细胞毒性和长荧光寿命的优势,实现了荧光碳点作为离体肿瘤细胞(HeLa 细胞) 标记和荧光寿命成像探针的应用,获得了高对比度的荧光寿命成像结果。通过将所得荧光碳点与普通油墨混合制备均匀分散的荧光墨水,可用于普通纸张及其他基材( 如柔性塑料薄膜、纺织品、衣服) 的荧光图案化,为固态荧光传感、荧光防伪标记和可穿戴光电子设备应用研究提供了基础。

关键词: 宏量     碳点     双光子     荧光寿命成像     图案化    

4Pi荧光超分辨显微术综述 Review

郝翔, 李依明, 傅爽, 李旸晖, 许迎科, 匡翠方, 刘旭

《工程(英文)》 2022年 第11卷 第4期   页码 146-153 doi: 10.1016/j.eng.2020.07.028

摘要:

自20 世纪90 年代以来,持续的科技进步突破了光学显微镜的衍射极限,使三维超分辨显微成像技术得以实现。回顾这些历程,一个重要的里程碑是基于两个对置物镜的4Pi 显微架构及其超分辨版本的出现。鉴于此,本文综述了4Pi 超分辨显微术的近期进展。总体上,4Pi 超分辨显微镜为透明样品观测提供了一
种能够突破衍射极限、非侵入、各向同性的三维分辨率的技术手段。具体而言,本文针对目标开关和随机开关两个主要4Pi 超分辨显微术版本,讨论了它们的架构、原理、应用和未来发展趋势。

关键词: 荧光超分辨显微术     超分辨成像     4Pi超分辨显微术     isoSTED     4Pi-SMLM    

Synthesis and characterization of 2,5-bis[4-(2-arylvinyl)phenyl]-1,3,4-oxadiazoles with two-photon fluorescence

ZHU Xiaoqin, QIAN Ying, LU Zhifeng

《化学科学与工程前沿(英文)》 2007年 第1卷 第4期   页码 381-384 doi: 10.1007/s11705-007-0069-6

摘要: Four novel 2,5-bis[4-(2-arylvinyl)phenyl]-1,3,4-oxadiazoles that exhibit strong two-photon absorption and enhanced two-photon excited fluorescence were designed and synthesized based on push-core-pull-core-push molecules built from embedding electron-transporting 1,3,4-oxadiazole in aromatic conjugated system through Wittig-Horner reaction. Their chemical structures were determined to show trans-vinylene character according to infrared (IR) and H nuclear magnetic resonance (NMR) spectra. A very effective energy transfer from the excited units to the ?-conjugated bridging unit can enhance the two-photon absorption and two-photon fluorescence.

关键词: 2-arylvinyl     trans-vinylene character     effective     fluorescence     push-core-pull-core-push    

hydrophobic environment triggering reactive fluorescence probe to real-time monitor mitochondrial DNA

《化学科学与工程前沿(英文)》 2022年 第16卷 第1期   页码 92-102 doi: 10.1007/s11705-021-2063-9

摘要: Mitochondrial DNA has a special structure that is prone to damage resulting in many serious diseases, such as genetic diseases and cancers. Therefore, the rapid and specific monitoring of mitochondrial DNA damage is urgently needed for biological recognition. Herein, we constructed an in situ hydrophobic environment-triggering reactive fluorescence probe named MBI-CN. The fluorophore was 2-styrene-1H-benzo[d]imidazole, and malononitrile was introduced as a core into a molecule to initiate the hydrolysis reaction in the specific environment containing damaged mitochondrial DNA. In this design, MBI-CN conjugates to mitochondrial DNA without causing additional damages. Thus, MBI-CN can be hydrolyzed to generate MBI-CHO in an in situ hydrophobic environment with mitochondrial DNA damage. Meanwhile, MBI-CHO immediately emitted a significative fluorescence signal changes at 437 and 553 nm within 25 s for the damaged mitochondria DNA. Give that the specific and rapid response of MBI-CN does not cause additional damages to mitochondrial DNA, it is a potentially effective detection tool for the real-time monitoring of mitochondrial DNA damage during cell apoptosis and initial assessment of cell apoptosis.

关键词: hydrolysis reaction     mitochondrial DNA damage     in situ hydrophobic environment trigger     fluorescence probe     apoptosis    

In vivo imaging of hematopoietic stem cell development in the zebrafish

Panpan Zhang, Feng Liu

《医学前沿(英文)》 2011年 第5卷 第3期   页码 239-247 doi: 10.1007/s11684-011-0123-0

摘要: imaging is crucial for developmental biology and can further help to follow cell development/differentiation in normal and pathological conditions. Recent advances in optical imaging techniques has facilitated tracing of the developmental dynamics of a specific organ, tissue, or even a single cell. The zebrafish is an excellent model for imaging of hematopoiesis due to its transparent embryo at early stage; moreover, different zebrafish hematopoietic stem cells (HSCs) transgenic lines have been demonstrated as very useful tools for illustrating the details of the HSC developmental process. In this review, we summarize recent studies related to the non-invasive imaging of HSC transgenics, to show that zebrafish transgenic lines are powerful tools for developmental biology and disease. At the end of the review, the perspective and some open questions in this field will be discussed.

关键词: hematopoietic stem cell     hematopoiesis     in vivo imaging     transgenics     zebrafish    

Insight into fluorescence properties of 14 selected toxic single-ring aromatic compounds in water: Experimental

Muhammad Farooq Saleem Khan, Jing Wu, Cheng Cheng, Mona Akbar, Chuanyang Liu, Bo Liu, Jian Shen, Yu Xin

《环境科学与工程前沿(英文)》 2020年 第14卷 第3期 doi: 10.1007/s11783-020-1219-z

摘要: The fluorescence peak location of 14 compounds interpreted at protein-like region. The p-electron system inside aromatic ring contributes to the fluorophore region. Functional group variation effects the emission spectra. Decrease in quantum yield and increase in DE is due to atomic weight F>Cl>Br>I. Theoretically results are in line with experimental ones. Various single-ring aromatic compounds in water sources are of great concern due to its hazardous impact on the environment and human health. The fluorescence excitation-emission matrix (EEMs) spectrophotometry is a useful method to identify organic pollutants in water. This study provides a detailed insight into the fluorescence properties of the 14 selected toxic single-ring aromatic compounds by experimental and theoretical analysis. The theoretical analysis were done with Time-Dependent Density Functional Theory (TD-DFT) and B3LYP/6-31G (d,p) basis set, whereas, Polarizable Continuum Model (PCM) was used to consider water as solvent. The selected compounds displayed their own specific excitation-emission (Ex/Em) wavelengths region, at Ex<280 nm and Em<340 nm, respectively. Whereas the theoretical Ex/Em was observed as, Ex at 240 nm–260 nm and Em at 255 nm–300 nm. Aniline as a strong aromatic base has longer Em (340 nm) than alkyl, carbonyl, and halogens substituted benzenes. The lone pair of electrons at amide substituent serves as a p-electron contributor into the aromatic ring, hence increasing the stability and transition energy, which results in longer emission and low quantum yield for the aniline. The fluorescence of halogenated benzenes illustrates an increase in the HOMO-LUMO energy gap and a decrease in quantum yield associated with atomic size (F>Cl>Br>I). In this study the theoretical results are in line with experimental ones. The understanding of fluorescence and photophysical properties are of great importance in the identification of these compounds in the water.

关键词: Fluorescence     Photophysical properties     Effect of the substituent     Toxic aromatic compounds    

Cd-tolerant electrochemically active bacteria in MECs toward exotic Cr(VI) based on the sensing of fluorescence

Xia Hou, Liping Huang, Peng Zhou, Hua Xue, Ning Li

《环境科学与工程前沿(英文)》 2018年 第12卷 第4期 doi: 10.1007/s11783-018-1057-4

摘要:

Cell membrane of indigenous Cd-tolerant EAB harbored more cadmium than chromium.

Indigenous Cd-tolerant EAB cytoplasm located more chromium than cadmium.

Simultaneously quantitatively imaging Cd(II) and Cr(III) ions in EAB was achieved.

Current accelerated the harboring of cadmium in EAB at an initial 2 h.

Current directed the accumulation of more chromium in EAB over time.

关键词: Microbial electrolysis cell     Electrochemically active bacteria     Cd-tolerant bacteria     Cd(II) and Cr(VI)     Fluorescence probe    

Synthesis, characterization and fluorescence quenching of conjugated polymer containing triphenylamine

LIU Feng, XIAO Jianhua, REN Weihua, HU Jun, LIU Honglai

《化学科学与工程前沿(英文)》 2008年 第2卷 第4期   页码 428-433 doi: 10.1007/s11705-008-0083-3

摘要: Poly(triphenylamine--phenylenevinylene)s with two different end-groups were obtained through a Wittig polycondensation. The structures of two copolymers were characterized. Ultraviolet and visible spectroscopy (UV-Vis) and photoluminescence (PL) spectra show the end-capped polymer emits intensive green light in both solution and film state. Their applications in the detection of nitro compounds were investigated, and the results show high fluorescence quenching sensitivity of the end-capped polymer towards -nitrotoluene (-NT). When the concentration of -NT was 21.5 × 10 mol/L, the fluorescence quenching reached 96%. Additionally, after the exposure of polymer film in three different quenchers such as dinitrotoluene (DNT), -nitrobenzoquinone (-BQ) and -nitrotoluene (-NT) for 600 s, its fluorescence quenching reached 93.6%, 11.5% and 77.9%, respectively. This kind of polymer has great advantages in preparation and may find applications in the detection of nitro explosives.

关键词: detection     different     fluorescence     UV-Vis     end-capped polymer    

标题 作者 时间 类型 操作

Carbon dots-based fluorescence sensor for two-photon imaging of pH in diabetic mice

期刊论文

A highly selective fluorescent probe for real-time imaging of UDP-glucuronosyltransferase 1A8 in living

期刊论文

SWIR Fluorescence Imaging In Vivo Monitoring and Evaluating Implanted M2 Macrophages in Skeletal

Mo Chen, Yuzhou Chen, Sijia Feng, Shixian Dong, Luyi Sun, Huizhu Li, Fuchun Chen, Nguyen Thi Kim Thanh, Yunxia Li, Shiyi Chen, You Wang, Jun Chen

期刊论文

荧光显纳镜在神经科学中的应用

王杨云逗, 林剑, 张启明, 陈希, 栾海涛, 顾敏

期刊论文

evaluation of renal function using diffusion weighted imaging and diffusion tensor imaging in type 2

null

期刊论文

基于临床可用的亚甲基蓝近红外二区成像用于泌尿系统结构及功能成像的研究

薛丁玮, 吴迪, 陆泽毅, Jochen Neuhaus, 阿卜杜热合曼·则比布拉, 冯哲, 成晟, 周静, 钱骏, 李恭会

期刊论文

Synthesis and fluorescence behavior of 2,5-diphenyl-1,3,4-oxadiazole-containing bismaleimides and bissuccinimides

Xin ZHANG, Zichen LI

期刊论文

荧光碳点的快速宏量制备及多功能应用

王丹,王志勇,詹求强,蒲源,王洁欣,Neil R. Foster,戴黎明

期刊论文

4Pi荧光超分辨显微术综述

郝翔, 李依明, 傅爽, 李旸晖, 许迎科, 匡翠方, 刘旭

期刊论文

Synthesis and characterization of 2,5-bis[4-(2-arylvinyl)phenyl]-1,3,4-oxadiazoles with two-photon fluorescence

ZHU Xiaoqin, QIAN Ying, LU Zhifeng

期刊论文

hydrophobic environment triggering reactive fluorescence probe to real-time monitor mitochondrial DNA

期刊论文

In vivo imaging of hematopoietic stem cell development in the zebrafish

Panpan Zhang, Feng Liu

期刊论文

Insight into fluorescence properties of 14 selected toxic single-ring aromatic compounds in water: Experimental

Muhammad Farooq Saleem Khan, Jing Wu, Cheng Cheng, Mona Akbar, Chuanyang Liu, Bo Liu, Jian Shen, Yu Xin

期刊论文

Cd-tolerant electrochemically active bacteria in MECs toward exotic Cr(VI) based on the sensing of fluorescence

Xia Hou, Liping Huang, Peng Zhou, Hua Xue, Ning Li

期刊论文

Synthesis, characterization and fluorescence quenching of conjugated polymer containing triphenylamine

LIU Feng, XIAO Jianhua, REN Weihua, HU Jun, LIU Honglai

期刊论文